Eppendorf BioSpectrometer® basic

Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
Eppendorf BioSpectrometer® basic
. Eppendorf BioSpectrometer® basic

Eppendorf BioSpectrometer® basic 使您的工作变得更加轻松,具有以下特点: 操作极其简便,引导化软件流程,直接在设备上操作,预编程方法,所测量数据自动计算,结果一目了然。 更多信息

Inquire Now

产品信息

Eppendorf BioSpectrometer basic 是一种小型、非常紧凑的分光光度计,易于操作,分析结果具有高度可重复性。 可以测量和记录紫外/可见光 (UV/Vis) 光谱范围,也可以测量从 200 nm 到 830 nm 的单个波长。 可自由选择的波长为当前和未来应用提供最大范围的灵活性。 除用于标准测量的预编程方法外,操作者还可以创建和存储他们自己的方法。 通过单个方法的循序渐进过程优化了的菜单导航指南。 显示所有必需项,重要数据无一或缺。 设置有帮助栏,用来解释操作顺序,且有 5 种不同语言可选。

产品特性

  • 对一个或多个波长的光线进行吸光度测量,记录波长扫描范围从 200  nm 到 830  nm(增量: 1 nm)
  • 自动评估并储存所测量的数据,结果一目了然
  • 通过光谱图显示样品纯度,并自动进行比率值计算
  • 具有预编程应用程序,可快速启动
  • 可自由编程应用程序以及可自由编程参数,通过系数、标准或标准系列进行评估
  • 双波长法,带减法或除法评估
  • 集成应用和结果记忆功能
  • 通过 USB 接口、以太网、电子邮件的方式传输结果或直接打印输出结果
  • 引导化软件流程,可减少误差
  • 集成自检和校准历史记录

应用

  • 核酸定量检测
  • 蛋白质直接定量检测 (UV 280 nm)
  • 通过 µCuvette G1.0 微量比色皿对高浓度样品进行微量检测
  • 细菌生长测定 (OD 600)
  • 通过比色法进行蛋白质定量测定,例如 BCA、Bradford、Lowry 法
  • 染料标记生物大分子(核酸或蛋白质)的结合率 (FOI) 评估
  • 可自由选择波长,例如,340 nm: NADPH 或 NAPH 测定,405 nm: 对硝基苯酚测定,420 nm: 邻硝基苯酚测定,490 nm: 比色法果糖测定,490 nm: 细胞毒性测定
 Eppendorf BioSpectrometer® basicEppendorf BioSpectrometer® basic
BSA 浓度范围7.5 ng/µL – 45.45 µg/µL
BSA 浓度范围 (UV 280 nm) µCuvette G1.075 ng/µL – 45.45 µg/µL
±0.03 µg/µL,A = 0
±0.076 µg/µL,A = 1 (0.5 %)
BSA 浓度范围 (UV 280 nm) UVette 10 mm7.5 ng/µL – 4.5 µg/µL
±0.003 µg/µL,A = 0
±0.007 µg/µL,A = 1 (0.5 %)
BSA 浓度范围 (UV 280 nm) UVette 2 mm37.5 ng/µL – 22.5 µg/µL
±0.015 µg/µL,A = 0
±0.038 µg/µL,A = 1 (0.5 %)
dsDNA 浓度范围2.5 ng/µL – 1,500 ng/µL
dsDNA 浓度范围 (UV 260 nm) UVette 10 mm2.5 ng/µL – 150 ng/µL
±0.1 ng/µL,A = 0
±0.25 ng/µL,A = 1 (0.5 %)
dsDNA 浓度范围 (UV 260 nm) UVette 2 mm12.5 ng/µL – 750 ng/µL
±0.5 ng/µL,A = 0
±1.25 ng/µL,A = 1 (0.5 %)
dsDNA 浓度范围 (UV 260 nm) µCuvette G1.025 ng/µL – 1,500 ng/µL
±1 ng/µL,A = 0
±2.5 ng/µL,A = 1 (0.5 %)
光源(吸收光)氙气闪光灯
光程高度8.5 mm
光谱带宽≤4 nm
发射波长 I 荧光
发射波长 II 荧光
吸光度测量范围0 A – 3.0 A (260 nm)0 A – 3.0 A
吸光随机误差≤0.002,A = 0
≤0.005 (0.5 %),A = 1
≤0.002,A = 0
≤0.005 (0.5 %),A = 1
吸收波长范围扫描波长 (nm): 200 – 830 nm,增量为 1 nm
吸收系统误差±1 % (A = 1)
扫描
操作指南语言西班牙语, 意大利语, 法语, 英语, 德语, 日语
方法记录>100 个方法程序
最小步进1 nm
检测原理(吸收光)带参比光束的单光束原子吸收分光光度测定
检测器类型CMOS 二极管阵列,1024 像素
检测器(荧光)N/AN/A
比色皿槽12.5 mm × 12.5 mm
波长系统误差≤0.5 nm
波长范围200 nm – 830 nm
波长选择增量1 nm
波长随机误差±1 nm
温度系统误差 
温度随机误差  
能耗约 15 W,操作期间
约 5 W,显示屏变暗后
荧光光源
荧光测量原理
荧光测量范围
荧光激发波长
随机误差(荧光)
接口› USB 主接口: 用于连接 U 盘和热敏打印机 DPU-S445
› USB 设备接口用于连接计算机
› 串行接口 RS 232: 用于连接热敏打印机 DPU-414
› 以太网接口 RJ45: 用于连接网络打印机
电源230 V, 50 – 60 Hz230 V, 50 – 60 Hz
尺寸(长 × 宽 × 高)295 × 400 × 150 mm / 11.6 × 15.7 × 6 in
带/不带配件时的重量5.4 kg
两测量点之间的间距
测量时间范围
温度控制范围

您可能需要